| Overall Specifications of Kirloskar Green Silent Gensets |
| Typical specifications of 415 V. 50 Hz. 3 phase Liquid - cooled silent gensets |
| |
Genset
Moedel
|
Kirloskar
Engine
Model
|
Rated output
at 1500
Continious bhp |
Maximum
recommended Genset
rating at 0.8 pf(KVA)
Prime continious |
Representative dimensions with
canopy
(Length X Width X Height)
mm |
Approx
weight with canopy
Kg. |
| KG20WS |
2R1040 |
27 |
20 |
2190 X 1275 X 2050 |
1, 200 |
| KG30WS |
3R1040 |
42 |
34 |
2520 X 1140 X 2160 |
1, 300 |
| KG40WS |
4R1040 |
56.3 |
45 |
3360 X 1160 X 2100 |
1, 500 |
| KG50WS |
4R1190 |
62 |
50 |
3350 X 1190 X 1650 |
1, 500 |
| KG62.5WS |
4R1040T |
83 |
62.5 |
3600 X 1440 X 2360 |
1, 700 |
| KG82.5WS |
4R1040TA |
105 |
82.5 |
3335 X 1375 X 2360 |
1, 950 |
| KG100WS |
6R1080T |
127 |
100 |
3900 X 1600 X 2500 |
2, 500 |
| KG125WS |
6R1080TA |
156 |
125 |
3900 X 1600 X 2500 |
2, 700 |
| KG140WS |
6SL9088TAI |
166 |
140 |
4630 X 1850 X 2890 |
3, 580 |
| KG160WS |
6SL9088TA |
198 |
160 |
4630 X 1850 X 2890 |
3, 720 |
| KG180WS |
6SL1500TAI |
235 |
180 |
4630 X 1850 X 2890 |
3, 870 |
| KG200WS |
6SL1500TA |
254 |
200 |
4630 X 1850 X 2890 |
3, 950 |
| KG250WS |
6SL8800TA |
310 |
250 |
5360 X 1870 X 2470 |
4, 300 |
| KG275WS |
6K12TA |
328 |
275 |
6000 X 2070 X 3340 |
3, 400 |
| KG320WS |
6K12TASrI |
386 |
320 |
6000 X 2070 X 3340 |
3, 400 |
| KG400WS |
8K15TA |
494 |
400 |
5500 X 2140 X 3480 |
4, 050 |
| KG500WS |
10K18TA |
602 |
500 |
5500 X 2140 X 3480 |
4, 550 |
| KG600WS |
12K22TA |
723 |
600 |
5700 X 2150 X 3690 |
5, 200 |
|
| |
| Overall Specifications of Kirloskar Green Silent Gensets |
| Typical specifications of 415 V. 50 Hz. 3 phase Air - cooled silent gensets |
| |
Genset
Moedel
| Kirloskar
Engine
Model
|
Rated output
at 1500 rpm
Continious bhp |
Maximum
continious
recommended Genset
rating at 0.8 pf(KVA)
Prime continious |
Representative dimensions with
canopy
(Length X Width X Height)
mm |
Approx
weight with canopy
Kg. |
| KG15AS |
HA - 294 |
19 |
15 |
2410 X 1120 X 1880 |
1, 150 |
| KG25AS |
HA - 394 |
32 |
25 |
2710 X 1100 X 1920 |
1, 300 |
| KG30AS |
HA - 494 |
43 |
30 |
3000 X 1140 X 1930 |
1, 500 |
| KG35AS |
HA - 494 |
43 |
35 |
3000 X 1140 X 1930 |
1, 500 |
| KG45AS |
HA - 494TC |
56 |
45 |
3200 X 1140 X 1940 |
1, 550 |
| KG55AS |
HA - 694 |
65 |
55 |
3970 X 1260 X 1880 |
1, 800 |
| KG70AS |
HA - 694T |
83 |
70 |
3980 X 1290 X 1895 |
1, 900 |
|
| |
| Notes : |
 |
All engine ratings are gross rated outputs to IS 10002, BS 5514, DIN 6271, ISO 3046. |
 |
All gensets ratings are according to ISO 8528. |
 |
Power reduction : From ambient conditions (altitude, air temperature, humidify) worse than the standard operating conditions, the engine output should be derated in accordance with relevant standards. Please consult KOEL for precise deration calculations. |
| |
In view of continuous product updation and design changes, all above specifications are subject to change without prior notice. |
|
| |
|
|